TRD1

Optimization of imaging conditions in pediatric dynamic chest radiography: a virtual imaging trial. SPIE Medical Imaging

Tanaka R, Segars W, Abadi E, Minami S, Samei E.
Optimization of imaging conditions in pediatric dynamic chest radiography: a virtual imaging trial.
SPIE Medical Imaging. 2022;12031.
https://doi.org/10.1117/12.2612720

Optimization of imaging conditions in pediatric dynamic chest radiography: a virtual imaging trial. SPIE Medical Imaging Read More »

Development of scalable lymphatic system in the 4D XCAT phantom: application to quantitative evaluation of lymphoma PET segmentations

Fedrigo R, Segars WP, Martineau P, Gowdy C, Bloise I, Uribe CF, Rahmim A.
Development of scalable lymphatic system in the 4D XCAT phantom: application to quantitative evaluation of lymphoma PET segmentations.
Medical Physics. 2022.
https://doi.org/10.1002/mp.15963

Development of scalable lymphatic system in the 4D XCAT phantom: application to quantitative evaluation of lymphoma PET segmentations Read More »

Quantitative analysis of changes in lung density by dynamic chest radiography in association with CT values: a virtual imaging study and initial clinical corroboration

Sugiura T, Tanaka R, Samei E, Segars WP, Abadi E, Kasahara K, Ohkura N, Tamura M, Matsumoto I
Quantitative analysis of changes in lung density by dynamic chest radiography in association with CT values: a virtual imaging study and initial clinical corroboration.
Radiological Physics and Technology. 2022;15(1):45-53.
https://doi.org/10.1007/s12194-021-00648-w

Quantitative analysis of changes in lung density by dynamic chest radiography in association with CT values: a virtual imaging study and initial clinical corroboration Read More »

Can photon-counting CT improve estimation accuracy of morphological radiomics features? A simulation study for assessing the quantitative benefits from improved spatial resolution in deep silicon-based photon-counting CT

Sharma S, Pal D, Abadi E, Sauer T, Segars P, Hsieh J, Samei E.
Can photon-counting CT improve estimation accuracy of morphological radiomics features? A simulation study for assessing the quantitative benefits from improved spatial resolution in deep silicon-based photon-counting CT.
Academic Radiology. 2022.
https://doi.org/10.1016/j.acra.2022.06.018

Can photon-counting CT improve estimation accuracy of morphological radiomics features? A simulation study for assessing the quantitative benefits from improved spatial resolution in deep silicon-based photon-counting CT Read More »

Dose coefficients for organ dosimetry in tomosynthesis imaging of adults and pediatrics across diverse protocols

Sharma S, Kapadia A, Ria F, Segars WP, Samei E.
Dose coefficients for organ dosimetry in tomosynthesis imaging of adults and pediatrics across diverse protocols.
Medical Physics. 2022;49(8):5439-50.
https://doi.org/10.1002/mp.15798

Dose coefficients for organ dosimetry in tomosynthesis imaging of adults and pediatrics across diverse protocols Read More »

Anatomically and physiologically informed computational model of hepatic contrast perfusion for virtual imaging trials

Sauer TJ, Abadi E, Segars P, Samei E.
Anatomically and physiologically informed computational model of hepatic contrast perfusion for virtual imaging trials.
Medical Physics. 2022;49(5):2938-51.
https://doi.org/10.1002/mp.15562

Anatomically and physiologically informed computational model of hepatic contrast perfusion for virtual imaging trials Read More »